Measurement and
Test Systems
Calibration
Systems
Vibration Control
Systems
Vibration and
Shock Exciter
Services
deutsch  english
SPEKTRA Schwingungstechnik und Akustik GmbH Dresden

  Calibration systems • Special equipment • DKD laboratory • Environmental simulation

Home I Imprint I Contact I Terms & Conditions

Primary Calibration Systems CS18

Based on years of continuous research and development, as well as cooperation with the Physikalisch-Technische Bundesanstalt (PTB) and Polytec, SPEKTRA has taken the lead in the world market for primary calibration systems for acceleration sensors and laser vibrometers.

The highest level of precision and a calibration traced back to an absolute physical measurand are the main reasons for utilizing a primary calibration system. National Institutes of Metrology (NIM) around the world are the main customers of primary systems, and many of the NIMs worldwide are satisfied customers of SPEKTRA CS18P primary calibration systems.

Absolute calibration with sine excitation
   

Calibration System CS18P HF
System for the absolute calibration at high frequencies

  • Signal form: Sinusoidal
  • Frequency range: 5 Hz ... 20 kHz

Data Sheet
Turn key laboratory solution

 
 

Calibration System CS18P VLF
System for the absolute calibration at very low frequencies

  • Signal form: sinusoidal
  • Frequency range: 0.2 Hz ... 160 Hz

Data Sheet
Turn key laboratory solution

 
Absolute calibration with shock excitation
   

Calibration System CS18P MS
System for the absolute calibration using medium-shock acceleration

  • Signal form adjustable or sinusoidal (full period)
  • 2 gN … 5,000 gN
  • fully / semi-automated
  • Pulse width 90 µs ... 400 µs

Data Sheet
Turn key laboratory solution

 
 

Calibration System CS18P HS
System for the absolute calibration using high-shock acceleration

  • Shock acceleration one period sinusoidal
  • 500 gN … 75,000 gN
  • fully / semi-automated
  • Pulse width 50 µs

Data Sheet
Turn key laboratory solution

 

Optional extras and special applications you will find at:

  CS18 Optional extras

 

Our laboratory has
been accredited by:


DKD-K-27801
 

   News
   

2010-05-11  
SPEKTRA on the exhibition Sensor + Test
Meet SPEKTRA in Hall 12, Stand 439
 
[more]  [more]  
   
2010-02-15  
Fulminating finish creates momentum into the future
SPEKTRA looks back on 2009 and gives an outlook on 2010
 
[more]  [more]  
   
2010-02-15  
Head of Development department receives doctorate
Scientific achievements honored by Technical University Braunschweig
 
[more]  [more]  
   
   

Representation of
in Germany:
APS Dynamics

 
   

  Calibration systems • Special equipment • DKD laboratory • Environmental simulation

Home I Imprint I Contact I Terms & Conditions

 
 

SPEKTRA Schwingungstechnik und Akustik GmbH Dresden

Gostritzer Straße 61 • 01217 Dresden • Germany