The employed modular design of the system allows the systems to be upgraded step by step and to effectively combine different systems up to primary systems.
For instance, practical combinations are CS18 VLF/LS for crash-test laboratories or CS18 P-HF/VLF for national institutes of metrology.
| Calibration systems for |
 |
|
Calibration by comparison with sine excitation |
 |
| |
|

|
CS18 VLF Calibration system
Ultra-low frequency calibration system for frequency range
0.4 Hz ... 160 Hz
Data sheet
|
| |
|
 |
CS18 LF Calibration system
Low-frequency calibration system for frequency range
3 Hz ... 5 kHz
Data sheet
|
| |
|
 |
CS18 MF Calibration system
Medium-frequency calibration system for frequency range
5 Hz ... 10 kHz
Data sheet
|
| |
|
 |
CS18 HF Calibration system
High-frequency calibration system for frequency range
5 Hz ... 20 kHz
Data sheet
|
| |
|
Potential users: DKD calibration laboratories, departments of quality assurance in industry, sensor manufacturers
|
Optional extras CS18 vibration |
Accessories case |
| |
|
 |
Optional extra CS18 TRANS
CS18 TRANS as an optional extra to a type CS18 VLF Calibration system. It is intended for operation in conjunction with an APS 500 or APS 129 air-bearinged longstroke vibration exciter in the frequency range
2 Hz … 50 Hz.
Data sheet
|
| |
|
 |
|
Calibration by comparison with shock excitation |
 |
| |
|
 |
CS18 LS Calibration system
Shock-pendulum calibration system with sinusoidal half-wave shock acceleration in the range of
10 gn … 200 gn
Data sheet
|
| |
|
 |
CS18 MS Calibration system
Medium-shock calibration system for sinusoidal single full-wave shock acceleration in the range of
20 gn … 4,000 gn
Data sheet
|
| |
|
 |
CS18 HS Calibration system
High-shock calibration system for sinusoidal single full-wave shock acceleration in the range of
1,000 gn … 100,000 gn
Data sheet
|
| |
|
| Potential users: Departments of quality assurance in the automotive industry |
Optional extras CS18 vibration |
Accessories case |
| |
|
 |
|
Absolute calibration with excitation by sine or shock |
 |
| |
|
| Based on years of continuous research and development as well as cooperation with Physikalisch-Technische Bundesanstalt (PTB) and Polytec, SPEKTRA has taken the lead on the world market in primary calibration systems for acceleration sensors and laser vibrometers. |
| |
|

|
CS18P VLF Calibration system
System for the absolute calibration at very low frequencies in the range of
0.4 Hz ... 80 Hz
Data sheet
|
| |
|
 |
CS18P HF Calibration system
System for the absolute calibration at high frequencies in the range of
5 Hz ... 20 kHz
Data sheet
|
| |
|
 |
CS18P MS Calibration system
System for the absolute calibration using high-shock acceleration of a single sine period in the range of
2 gn … 5,000 gn
Data sheet
|
| |
|
 |
CS18P HS Calibration system
System for the absolute calibration using high-shock acceleration of a single sine period in the range of
500 gn … 75,000 gn
Data sheet
|
| |
|
Potential users: National institutes of metrology, DKD calibration laboratories, industrial departments for quality assurance, sensor manufacturers
|
Optional extras CS18 vibration |
Accessories case |
| |
|
 |
|
Calibration systems for laser vibrometers |
 |
| |
|
All primary calibration systems by SPEKTRA include a laser vibrometer standard traced back to PTB and so are suited to the calibration of laser vibrometers and digital laser vibrometer standards.
CS18P
|
| |
|
| |
 |
|
Calibration of static acceleration sensors |
 |
| |
|
CS18 STAT Calibration system
Calibration of static acceleration
sensors using the local gravitation
field of ± 1 gn
Adjustable tilt 0° ... 360°
Data sheet
|
Optional extra PR measurement
Calibration of static acceleration
sensors using the local gravitation
field of ± 1 gn
Data sheet
|
| |
|
| |
 |
|
Calibration of signal conditioners |
 |
| |
|
Optional extra CAL - Q - U - ICP is available for each of the CS18 calibration systems. This complementary set of hardware and software enables charge, voltage and ICP® amplifiers as well as microphone preamplifiers to be calibrated with respect to amplitude and phase.
Data sheet
|
 |
|
Further information |
 |
| |
|
Optional extras CS18 vibration |
Accessories case |
CS18 General brochure |
| |
|